Plate Beam Design
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
Using the results obtained from the analysis of the entire structure and additional design data, automatically design concrete plate beam members according to the AASHTO-LRFD 16 and Eurocode. |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
From the Main Menu select Design > RC Design > Concrete Code Design > Plate Beam Design. Shortcut key : [Ctrl]+3 |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
The automatic design results of
sub-domain are calculated for negative, positive bending moments
and shear forces at five positions The results appear in blue when the automatic design for the given properties is satisfactory, otherwise they appear in red, which represent the results are unsatisfactory. The plate design results are produced in the unit length selected by the user. Sub-Domain : Name of sub-domain. SEL : Select sub-domain for redesign and production of results. Major Dir : Main rebar direction CHK : Status of automatic design results (Results are produced in state for convenience.
The above symbols representing the status are combined to show "OK, OK++, OK--, etc. Pos :
The design results for Pos and Neg reflect the automatic design
for maximum required reinforcement area for the positive Req_As :
The area of required rebars
(LengthUnit2 / LengthUnit)
for the bending moment calculated
by the program. Elem. : Element number. Node : Node number. LCB_M : Load combination which causes the maximum required reinforcement due to bending moment of specific sub-domain. Mu : Maximum factored bending moment occurring in the node of element of relevant sub-domain under the load combination displayed in LCB_M. Mr : Bending moment resistance calculated by the program of the plate element. Ratio_M :
Ratio of the factored bending moment to the design bending moment
strength. The ratio larger than 1 signifies, LCB_V : Load combination which causes the maximum required reinforcement due to shear force of specific sub-domain. Vu :
Maximum factored shear force occurring in the node of element
of relevant sub-domain under the load combination Vr : Shear force resistance calculated by the program of the plate element. Ratio_V :
Ratio of the factored shear force to the design shear strength.
The ratio larger than 1 signifies, the design is As_V : The quantity of shear rebars auto-calculated by the program of the sub-domain from the inputted stirrup data. Stirrup : Size and spacing of stirrup provided by the user. Note Req_As is calculated using iterative
method. 1st and 2nd iteration use minimum
and maximum reinforcement area respectively. Common Control : Display the applicable code for strength verification. : Display the unit system selected by the user. : Select all members : Cancel the selection of all members Re-verify the strengths of the selected members. When the strength re-verification is executed from the results displayed by section properties all the elements attributed to the same sections are included : Display detail strength verification results : Display simplified strength verification results : Produce the strength checking results in summary calculations for the selected members
:
Produce the strength verification
results in detail calculations for the selected members. All: Produce all the strength checking results in the Checking Results dialog box OK: From the strength checking results, display only the checking results that have met the design requirements (OK) in the Checking Results dialog box NG: From the strength checking results, display only the checking results that have not satisfied the design requirements (NG) in the Checking Results dialog box : Check in the option to select and highlight the selected members in Model View. : Close the dialog box. |
||||||||||||||||||||||||||||||
|