Cable Efficiency |
|
|
Check the cable efficiency in a spreadsheet table format. Table Tool in midas Civil offers a variety of powerful, built-in functions. Refer to Usage of Table Tool for detailed directions. |
|
|
|
From the Main Menu select Results > Result Tables > Cable> Cable Efficiency |
|
|
Upon executing Cable > Cable efficiency Table, Records Activation Dialog is displayed. Click Note Refer to Usage of Table Tool and check the following data: Elem : ID number of elements Node I : Node ID number at Section I Node J : Node ID number at Section J Load : Loading condition Chord Length (m) : Length of the chord ExA (tonf) : (Modulus of elasticity) x (cross-sectional area of the cable) Weight (tonf) : Total weight of the cable Tension (tonf) : Cable tension ExA(mod) Efficiency : cable efficiency where, G = Total weight of the cable L = Length of the chord H = Horizontal component of cable tension T Ec = Modulus of elasticity Ac = Cross sectional area of the cable α = Angle of the cable |
|