Data
for Strength Auto-Calculation of Hinges
Reference Location for Distributed
Hinges
Beams:
Select the reference location for auto calculation ( I-End,
Center or J-End)
Fiber
Model Option
Beam-Column
Consider Reinforcement Area:
Reinforcement area is deducted from the concrete fiber when this
option is activated.
Number
of Divisions
Core:
Area of section lying inside the center line of provided
reinforcement in the section for checking under the design tab.
Fiber Areas
Auto Size: Fibers are automatically
divided with finer size near edge and coarser size near core.
Equal-Size: All the fibers
are equally divided.
Ny (y-dir): Number of
divisions along local y-axis of the fiber section.
Nz (z-dir): Number of
divisions along local z-axis of the fiber section.
Cover:
Area of section lying outside the center line of provided
reinforcement in the section for checking under the design tab.
Fiber Areas
Auto Size: Fibers are automatically
divided with finer size near edge and coarser size near core.
Equal-Size: All the fibers
are equally divided.
Ny (y-dir): Number of
divisions along local y-axis of the fiber section.
Nz (z-dir): Number of
divisions along local z-axis of the fiber section.
Note
If reinforcements
are not defined from the section under the design tab, then input
for cover would be ignored and division would be done based on
input for core region. |