Tendon Location for Composite Section

 

 

 

Specify a part of composite section, through which a selected tendon profile is passing. This data is used to calculate the net area of prestressed concrete section.

Note 1
If this is not specified, it is assumed that tendon profiles pass through Part 1
.

 

 

 

From the Main Menu select Load >  Temp/Prestress > Tendon Profile > Tendon Location for Composite Section

 

 

 

Tendon Location for Composite Section

Tendon Profile: Select a tendon profile.

Composite Section for C.S.: A composite section for construction stage is automatically selected based on the selected tendon profile.

Part number: Specify part number through which a selected tendon profile passes.