Flexural Strength Data

 

 

Displays the critical condition of the flexure strength as per the Strength Limit State of Bridge Load Rating Design.

 

 

 

From the Main Menu select Design > Bridge Rating Design > Rating Design > Rating Design Result Tables > Flexural Strength Data.

 

 

Flexural Strength Data

Group:User Specified element group name.

Elem.:Designed element.

Part:The Location of the member  [node or node].

Rating Case:The design condition that will generate corresponding member results.

Rating Factor: Minimum Rating Factor.

Mn: Flexural Resistance.

DC

Factor: The DC load case factor inputted in Bridge Load Rating Setting.

Force (tonf-m):The moment about the primary axis due to DC load case.

DW

Factor:The DW load case factor inputted in Bridge Load Rating Setting.

Force (tonf-m):The moment about the primary axis due to DW load case.

Temperature

Factor:The Temperature load case factor inputted in Bridge Load Rating Setting.

Force (tonf-m): The moment about the primary axis due to Temperature load case

Permanent

Factor:The Permanent load case factor inputted in Bridge Load Rating Setting.

Force (tonf-m):The moment about the primary axis due to Permanent load case.

Secondary

Factor:The Secondary load case factor inputted in Bridge Load Rating Setting.

Force (tonf-m): The moment about the primary axis due to Secondary load case.

User Defined

Factor:The User Defined load case factor inputted in Bridge Load Rating Setting.

Force (tonf-m):The moment about the primary axis due to User Defined load case.

Pri.LL

Factor: The Primary Live Load factor inputted in Bridge Load Rating Setting.

Force (tonf-m):The moment about the primary axis due to Primary Live Load.

Adj.LL

Factor:The Adjacent Live Load factor inputted in Bridge Load Rating Setting.

Force (tonfm):The moment about the primary axis due to Adjacent Live Load.

Note

If the result does not satisfy the standard specification of design, then it is displayed in red.