Position for Rating Output
|
|
|
This feature enables the user to select the ends of element for which rating results are to be produced in Excel report generated from Excel Report after performing Rating Design. If no element is selected in Position for Rating Output, then no element result is produced in the report. |
|
|
|
From the Main Menu select Rating > Steel Bridge > Position for Rating Output |
|
|
Option Add/Replace: Add/Replace the position for Excel format rating output Delete: Delete the rating output position defined previously for the selected element Part I: Check rating design results only at i-end J:Check rating design results only at j-end I & J:Check rating design results at both ends Filters for Load Rating Summary Strength (Flexure): Most critical elements are printed in Load Rating Result Table of Excel Report. Select All in order to find the most critical elements from all composite sections. Select Group to limit the target elements to find out the most critical elements. Strength (Shear): Most critical elements are printed in Load Rating Result Table of Excel Report. Select All in order to find the most critical elements from all composite sections. Select Group to limit the target elements to find out the most critical elements. Service: Most critical elements are printed in Load Rating Result Table of Excel Report. Select All in order to find the most critical elements from all composite sections. Select Group to limit the target elements to find out the most critical elements. Click [Apply] to assign. |
|