Load Combination Type

 

 

Select the load combinations to be considered for steel composite design and classify them under Strength, Service, Fatigue 1 and Fatigue 2 load combinations.

Load Combination Type is only supported for AASHTO-LRFD07 and AASHTO-LRFD12.

Note
1. Load combinations specified under 'Composite Steel Girder Design' tab only, is considered for composite design as per AASHTO code.

2. Auto generated load combinations are automatically classified under Strength, Service and Fatigue 1/2 combinations.

 

 

 

From the Main Menu select Design > Composite Design > Load Combination Type

 

 

 

Load Combination List

Select the Load Combination which you want to consider for steel composite design. Load combination generated under 'Composite Steel Girder Design' tab only, appear in this list.

Strength Limit State

Select the load combinations classified for Strength Limit State as per Table 3.4.1-1 of AASHTO-LRFD 2012.

Service Limit State

Select the load combinations classified for Service Limit State as per Table 3.4.1-1 of AASHTO-LRFD 2012.

Fatigue 1 Limit State

Select the load combinations classified for Fatigue 1 Limit State as per Table 3.4.1-1 of AASHTO-LRFD 2012. Fatigue 1 load combination is used for infinite life design.

Fatigue 2 Limit State

Select the load combinations classified for Fatigue 2 Limit State as per Table 3.4.1-1 of AASHTO-LRFD 2012. Fatigue 2 load combination is used for finite life design.

Note
Extreme event load combinations are not considered for steel composite design in midas Civil. Thus they cannot be classified as a category using Load Combination Type option.