Function
Prestressing forces in tendons listed in a spreadsheet format table. The values may be entered or modified.
Table Tool in MIDAS/Gen offers a variety
of powerful built-in functions. Refer to the following items for detail
directions:
Basic directions (Cell motion, selection, size control, etc.)
Data manipulation (Add, delete, modify data, etc.)
Copy/Paste data using clipboard
Supplementary functions by Table types
Call
From the Main Menu select Load > Load Tables > Beam Section Temperatures.
Select Structure Tables > Static Loads > Beam Section Temperatures in the Tables tab of the Tree Menu.
Entry (Refer to "Tendon Prestress Loads")
Refer to Usage
of Table Tool and enter or modify the following data:

Tendon: Tendon name for which prestress loads are defined
Load Case: Load case name representing the prestress loads
Type: Type of prestress
Jacking: Order of pretensioning between the beginning and end of the tendon
Stress Begin: Prestress at the beginning of the tendon in the stress unit
Stress End: Prestress at the end of the tendon in the stress unit
Force Begin: Prestress at the beginning of the tendon in the force unit
Force End: Prestress at the end of the tendon in the force unit
Grouting: Timing for grouting Duct after prestressing
Group: Load Group Name