Revision of Ver.7.4.1
Function
Specify pretension loads for Truss elements or tension-only elements (hook & cable). Or, modify or delete previously specified loads.
This load cannot be used for performing analysis with materials having nonlinear properties.
Call
From the Main Menu select Load > Prestress Loads > Pretension Loads.
Select Static Loads > Prestress Loads >Pretension Loads in the Menu tab of the Tree Menu.
Entry
Load Case NameAssign the load case name. Click to the right to enter, additional load cases and modify or delete existing load cases.
Load Group NameSelect the desire Load Group that will include the entered Pretension Loads data. Select "Defualt", if a Group assignment is unnecessary. Click to the right to add, modify or delete Load Groups.
OptionsAdd: To enter new or additional pretension loads Replace: To replace previously entered pretension loads Delete: To delete previously entered pretension loads
Pretension LoadEnter positive (tension) or negative (compression) pretension load. Note |