Text Output is proceeded by entering
the required information step-by-step until the final result is
obtained.
If Text Output
is selected, the Text Printout Wizard dialog box that
selects the output load sets appears as shown in the figure.
Step Option
Specify the method of producing the
output with respect to the steps when a construction stage or
geometric nonlinear analysis is carried out.
All
Steps: Output the analysis results for all the steps.
Last
Step: Output the analysis results for the last step of
the corresponding stage.
A Load Set is a collection of load
combinations. Each Load Set serves a different purpose for output
production, such as member force, nodal displacement, support
reaction, etc.
Click to display
the following Load Set entry dialog box :
Enter the load set name. Check in
( ) the required load
cases/load combinations/envelopes and click
to register the load set. If required, click
or
to modify or delete the registered Load Set.
When all the required load sets are
registered, click to
proceed to the entry dialog box in the next step.
In
the Element Output Selection dialog box, choose the types
of elements to be output and the output mode. First, select
a load set from the registered load sets and the element types
to be output. Only the relevant elements used in the model
are activated in the dialog box. Click
to the right of the element types to set the details for the
element's output.
Set
output details by element types
The Element Selection Detail dialog
box has two parts: the filter setting part for the selection of
the elements to be output to the left and the part for the output
type and other items to the right. Filter can be applied to ID,
Section, Material, Story, Named Plane and Group. Only the elements
satisfying all the attributes selected in Filter are finally output.
The elements that satisfy the filter conditions are arranged in
the [Filter:] field. The elements previously selected in the window
before starting Text Output are arranged in the [PreSel:] field.
The assemblage of these two parts is finally output.
The output modes can be assigned
in Select Output. Frc and Str stand for Force and Stress respectively.
If [Min/Max by Property] is selected, the maximum and minimum
values for each section type can be checked.
When
the setting of element output is completed, click to
proceed to the setting of displacements and reactions output.
The procedure is similar to elements output.
Separate load sets can be applied
to different items, and as such separate load combinations can
be applied depending on the purpose for the output.
The
Result Output List dialog box for the output sequence and
the filename is displayed.
The output order can be sorted by
default and by types. Changes are possible by individually selecting
and dragging with the mouse. Check in [Insert form feed at each
output end] to insert a page mark in the document at the end of
each output. Write the output file path and name in the File Name
field and click to
create the document and view the created file in the Text Editor.
Refer to the Output section for producing output using the Text
Editor.
|