Story Drift Table

 

 

 

Check the story drifts due to static and dynamic loads in a spreadsheet format table.

 

"Story Shear Force Ratio" in "Model/Building/Control Data" must be checked for this function, which is checked as the Default.

 

The types of story drifts, which can be checked in Story Drift Table, are as follows:

 

1. Maximum Drift

 

2. Drift at the Center of Mass

 

3. Average Drift of Vertical Elements at each floor

 

4. Drift of Selected Node Line, which passes through a node selected by user vertically

 

5. Average Drift of Extreme Nodes Lines

 

6. Shear Weighted Average Drift of Vertical Elements

 

When "Story Shear Force Ratio>Consider Story Module" is checked in the "Model/Building/Control Data", accurate shear forces can be obtained for the story having the overlapping Module.

 

When Modules are defined in Structure > Building > Story  > Define Module button, the Module data is displayed in the first column of the table.

 

When the ratios exceed the allowable limit, they appear in red and 'Irregular' is printed in the Remark.

 

Table Tool in midas Gen offers a variety of powerful built-in functions.  Refer to Usage of Table Tool for detail directions.

 

 

 

From the Main Menu select Results > Tables > Result Tables > Story > Story Drift.

 

 

 

 

 

From Records Activation Dialog, select the load cases for which story drifts will be calculated.

 

Refer to Usage of Table Tool and check the following data:

 


 

Story Drift Parameters

 

The user provides the data for calculating modified story drifts and P-Delta incremental factors.  These are required values for generating the table.  When Table is invoked, the set Story Drift Parameters window is executed first.  

 

Response Modification Coefficient: It is applied to the calculation of Modified Story Drift.

 

Deflection Amplification Factor(Cd): It is applied to the calculation of Modified Story Drift.

 

Importance Factor: It is applied to the calculation of Modified Story Drift.

 

Scale Factor: Cm, Scale-up Factor. It is applied only to the response spectrum load cases or load combinations containing response spectrum load cases based on ASCE7-10, "12.9.4 Scaling Design Values of Combined Response".

 

Vertical Load Combination: Define a vertical load condition to consider the P-Delta effect.

 

Note
All the items other than Response Modification Coefficient are applied only for IBC and KBC.
 

 

Define Beta: Selection of Beta values.  In case of User Define, values for each story can be directly entered.

 

 

When Modules are not defined

 

Drift(X): Story drift in GCS X-direction (Click lower left tab)

 

Drift(Y): Story drift in GCS Y-direction (Click lower left tab)

 

Drift(Combined): Combined story drift of both GCS X, Y-directions (Click lower left tab)  

 

 

 

Load Case: Unit load case/combination

 

Story: Story ID

 

Story Height: Story Height

 

P-Delta Incremental Factor(ad): When P-Delta analysis is performed, the incremental factor becomes 1.0 irrespective of calculation results.

 

Note
For a story drift used for calculating the P-Delta Incremental Factor (ad), the "Maximum Drift of All Vertical Elements"is used. (Story drift as per "Story Drift Calculation Method" is not used in calculating the P-Delta Incremental Factor (ad) since the values are different depending upon the method used.)

Allowable Story Drift Ratio

 

 

1. Maximum Drifts of All Vertical Elements

 

Maximum drifts are produced for each story.

 

Node: Node numbers corresponding to the maximum story drifts at each story level

 

Story Drift: Incremental lateral displacement over two consecutive story levels

 

Modified Drift

 

When Response Modification Coefficient option is not selected:

Modified Drift =  ad * Story Drift * Cd * Scale Factor / Ie

When Response Modification Coefficient option is selected:

Modified Drift = ad * Story Drift * Response Modification Coefficient (RMC) *Scale Factor

 

Story Drift Ratio: Modified Drift / Story height

 

Remark: Acceptance of story drift ratio relative to the allowable story drift ratio

 

 

2. Drift at the Center of Mass

 

Difference in lateral displacements at the centers of mass at top and bottom ends is produced.

 

Drift Factor (Maximum / Current): Maximum story drift / Story drift at center of mass

 

Refer to Maximum Drift for the remainder.

 

 

 

3. Average Drift of Vertical Elements

 

Average story drift at a corresponding story is produced.

 

Drift Factor (Maximum / Current): Maximum story drift / Drift at the selected node line

 

Refer to Maximum Drift for the remainder.

 

Note
The items 3, 4, 5 & 6 are produced by right-clicking the mouse on the table followed by selecting specific items in 'Select Calculation Method'.

 

 

4. Drift of a Vertical Line on Selected Node

 

Story drifts at a user selected node and the nodes, which are located on the vertical line passing the selected node, are produced.

 

Drift Factor (Maximum / Current): Maximum story drift / Story drift at user-selected node

 

Refer to Maximum Drift for the remainder.

 

 

5. Average Drift of Vertical Lines on Selected Nodes

 

Average story drifts of building column lines selected by the user are produced.  The column lines here should be selected at the extremities of the building plan.

 

Drift Factor (Maximum / Current): Maximum story drift / Average story drift of the building plan extremities

 

Refer to Maximum Drift for the remainder.

 

 

 

  6. Shear Weighted Average Drift of Vertical Elements

 

Shear forces in the vertical members are reflected into the story drifts.

 

The shear weighted average drift is produced only when the 'Story Shear Force Ratio of Member' option is applied in Model>Building>Control data.

 

Story Drift:

 

: member shear force at story

 

: horizontal displacement of each story member

 

Drift Factor (Maximum / Current): Maximum story drift / shear weighted average story drift

Refer to Maximum Drift for the remainder.

 

 

 

When Modules are defined

 

The Module column is generated only when the Modules are defined. Story drifts are calculated as per the following Note.
 

Drift(X): Story drift in GCS X-direction (Click lower left tab)

 

Drift(Y): Story drift in GCS Y-direction (Click lower left tab)

 

Drift(Combined): Combined story drift of both GCS X, Y-directions (Click lower left tab)

 

 

 

Note
Method of calculating Story Drift for each Module

 

 

Module Example

 

 

 

 

1. Story drifts for the top floors of each Module are not generated.

 

2. Maximum Drift of All Vertical Elements

 

Drift at 4F of A_Module (left) is the maximum of story drifts for all the vertical elements at 4F (differences between the displacements at 4F and 5F). Drift at 4F of B_Module (right) is the maximum of story drifts for all the vertical members at 4F (differences between the displacements at 4F and 6F). Drift at 4F of C_Module (base) is not generated.

 

3. Drift at the Center of Mass

 

1) For a story assigned with Story Diaphragm:

 

The drift at 4F of A_Module (left) is the difference between the displacement at a point on 4F, which is generated when the Diaphragm Center (Mass Center) of 5F is projected on 4F, and the displacement at Mass Center of 5F. The drift at 4F of B_Module (right) is similarly calculated. A projected point on 4F is assumed to be included in the Diaphragm of 4F when calculating the displacement.

 

2) For a story without Story Diaphragm:

 

Average story drifts of vertical elements are used. To consider the case when specific wall elements are divided into smaller elements, first obtain the average drifts for each area and then obtain an average of all the average drifts.

 

Ex) When 5F is assigned with a diaphragm and 4F not assigned with a diaphragm (slab is modeled by using plate elements), the drift is the difference between the displacement at diaphragm center of 5F and the average displacement of vertical elements at 4F.

 

Module: Module name is defined in Structure > Building > Story  > Define Module button.

 

Load Case: Unit load case/combination

 

Story: Story ID

 

Story Height: Story Height

 

P-Delta Incremental Factor(ad): When P-Delta analysis is performed, the incremental factor becomes 1.0 irrespective of calculation results.

 

Note

For a story drift used for calculating the P-Delta Incremental Factor (ad), the  Maximum Drift of All Vertical Elements is used. (Story drift as per Story Drift Calculation Method is not used in calculating the P-Delta Incremental Factor (ad) since the values are different depending upon the method used.)

Allowable Story Drift Ratio

 

 

1. Maximum Drifts of All Vertical Elements

 

Maximum drifts are produced for each story.

 

Node: Node numbers corresponding to the maximum story drifts at each story level

 

Story Drift: Incremental lateral displacement over two consecutive story levels

 

Modified Drift

 

When Response Modification Coefficient option is not selected:

Modified Drift =  ad * Story Drift * Cd * Scale Factor / Ie

When Response Modification Coefficient option is selected:

Modified Drift = ad * Story Drift * Response Modification Coefficient (RMC) *Scale Factor

 

Story Drift Ratio: Modified Drift / Story height

 

Remark: Acceptance of story drift ratio relative to the allowable story drift ratio

 

 

2. Drift at the Center of Mass

 

Difference in lateral displacements at the centers of mass at top and bottom ends is produced.

 

Drift Factor (Maximum / Current): Maximum story drift / Story drift at center of mass

 

Refer to Maximum Drift for the remainder.

 

 

 

3. Average Drift of Vertical Elements

 

Average story drift at a corresponding story is produced.

 

Drift Factor (Maximum / Current): Maximum story drift / Drift at the selected node line

 

Refer to Maximum Drift for the remainder.

 

Note
The items 3, 4, 5 & 6 are produced by right-clicking the mouse on the table followed by selecting specific items in 'Select Calculation Method'.

 

Story drifts at a user selected node and the nodes, which are located on the vertical line passing the selected node, are produced.

 

Drift Factor (Maximum / Current): Maximum story drift / Story drift at user-selected node

 

Refer to Maximum Drift for the remainder.

 

 

5. Average Drift of Vertical Lines on Selected Nodes

 

Average story drifts of building column lines selected by the user are produced.  The column lines here should be selected at the extremities of the building plan.

 

Drift Factor (Maximum / Current): Maximum story drift / Average story drift of the building plan extremities

 

Refer to Maximum Drift for the remainder.

 

 

 

6. Shear Weighted Average Drift of Vertical Elements

 

Shear forces in the vertical members are reflected into the story drifts.

 

The shear weighted average drift is produced only when the 'Story Shear Force Ratio of Member' option is applied in Model>Building>Control data.

 

Story Drift:

 


: member shear force at story

 

: horizontal displacement of each story member

 

Drift Factor (Maximum / Current): Maximum story drift / shear weighted average story drift

 

Refer to Maximum Drift for the remainder.