midas Gen
MGT File
Save the model
data as a fn.MGT text file of midas Gen.
Note
When
exporting to a Text Format (MCT) file, the user now has an option
of including/excluding the syntax format comments.
MXT File
(for FEA/GTS)
Save
the model data as a fn.MXT text file. midas Civil model data such
as node, element, properties, boudaries, loads, and analysis control
data can be transferred to midas FEA/GTS.
Note
Cross-sections
data that are not supported in midas FEA are imported as user-type
section. Cable elements are imported as truss elements.
Nodal Results
(for GTS)
Save
the load data as text file. The file contains the following information.
-
Construction Stage
-
Load Case or Load Combination
-
Result Type as Reaction or Displacement
-
Result Components as Dx, Dy, Dz, Rx, Ry, Rz.
AutoCAD
DXF File
Save the model
data as an AutoCAD DXF file.
Frame Section
for Solid
By using frame
section information, create a solid geometry file that can be
exported to midas FEA.
Target Elements:Select elements
to be exported. If any selected element is assigned in Tapered
Section Group, "Convert to Tapered Section" must be
preceded before the selection.
Division in element:Enter the
number of division in element. It is recommended to increase the
number of division if there is any significant changes in tendon
profile.
Tendon Profile:Exported together
with frame section information.
Frame Section
for Plate
By using frame
section information, create a surface geometry file that can be
exported to midas FEA.
Target Elements For Detail Geometry
Model:Select elements to be exported.
Sub Frame Element:Elements selected
as Sub Frame Element are connected as frame elements at centroid.
Cross-sectional constant are saved as Value Type.
Specific Displacement:Displacement
results as per selected load cases/combinations are inputted as
pre-defined displacement in a detailed analysis model. pre-defined
displacement can be applied only after analysis is completed.
IFC File
Save the model
data as an IFC file.
Note.
IFC
file contains only geometry data such as section data and element
type, and element dimension. It does not contains loads, boundary
conditions, and analysis control data.
Section and Material properties
excepting for SRC section, Hollow Section, and Tapered section
are supported. SRC section, Hollow Section, and Tapered
sections are displayed as 1D line without section shape. Composite
type section will be excluded in IFC file.
Section property includes only section
shape and dimension of section. It does not support section stiffness
or DB name.
|