Equivalent Moment Factor (CmLT) Table
|
|
|
Display the bending coefficients arranged in a table in the order of element numbers.
Modify/Delete or Add New coefficients while reviewing the entered data .
*Marked as Equivalent Moment Factor (CmLT) for Eurocode. |
|
|
|
From the Main Menu select Design > Cold Formed Steel Design > Cold Formed Steel Design Tables > Equivalent Moment Factor (CmLT)
*Marked as Equivalent Moment Factor (CmLT) for Eurocode. |
|
|
When the table shown is displayed, the user may select relevant items to Modify/Delete, or Add New data.
Elem: Element number
Auto Calculate: Option to auto-calculate the bending coefficient (Cb)
Cb: Bending coefficient (*Marked as Equivalent Moment Factor (CmLT) for Eurocode.)
|
|