Modify Wall Mark Data

 

 

 

Enter the group names or individual names for the purpose of classification of shear walls for automatic design or strength verification.

 

 

 

From the Main Menu select Design > Design > RC Design > Modify Wall Mark Data.

 

 

 

Wall Mark

 

Enter the group or individual names to classify shear wall members.

 

Name: Group or individual name that classifies the shear wall members (refer to Note 1)

 

Wall ID. List: List of shear wall member numbers

 

The shear wall ID numbers can be entered in the entry field directly by the user or by selecting (picking) with the mouse in the analysis model.

 

 

 

Operation

 

Add, modify or delete shear wall member names defined by a group of shear wall ID numbers.

 

 : Add the entered name for shear wall members.

 

 : Update the previously defined name for shear wall members.

 

 : Delete the selected name for shear wall members.

 

 : Close the entry dialog bar.

 

 

Note 1
When the Wall Mark name is not defined by the user, the program automatically creates the names as follows. A name can be as long as
a maximum of 12 characters.

 

Name = "wM" + Shear Wall ID

 

Note 2
When the Wall Mark name is repeatedly entered for the same shear wall members, the Wall Mark name will be
updated to the last name entered.