Column Strip Checking

 

 

 

Produce the column strip check results considering the unbalanced moment.

 

Note
In order to use this function, KDS41 30 :2018 or KCI-USD12  must be selected in Design > Concrete Design Parameter > Design Code.

 

 

 

 From the Main Menu select Design > Design > Meshed Slab/Wall/Shell Design > Column Strip Checking.

 

 

 

 

Load Combinations

 

Select a desired load case or load combination.

Click  to the right to enter new or modify existing load combinations. (Refer to "Static Load Cases / Combinations")

 

 

     Force Options

 

 

Element: Display the contour using the internal forces calculated at each node of an element.

 

Avg. Nodal: Display the contour using the average internal nodal forces of the contiguous elements sharing the common nodes.

 

Note

Avg Nodal does not consider the simultaneity for the load case in which maximum member forces are displayed about all elements such as Moving Load Case, Settlement Load Case and Time History Load Case.

 

 

Type of Display

 

 Define the type of display as follows:

 

 

Components

 

Rebar

Display the column strip reinforcement status by diameter and spacing.

 If you check the Slab Design Result checkbox at the bottom, you can check the middle strip result.

 

As (m^2/m)

Display the area of the required reinforcement.

 

 

Resistance Ratio

Display the ratio of the design strength

 

Bending Moment Diagram

Display the bending moment diagram of the column strip

 

Unbalanced Moment

Display the unbalance moment of the column strip, and the strength ratio considering the unbalance moment (KCI2012 7.12.7 Commentary) at the node position of the column.

 

 

 

Operations

 

: Produce the result of code check  in a text format.