Thickness
Data dialog box (Value)

Thickness
Data dialog box(Stiffened)
To
enter new or additional thickness data
Click
in the Properties dialog box and enter the following items :
Value
Thickness
ID: Thickness numbers of planar elements (Auto-set to the
last thickness number +1)
In-plane
& Out-of-plane: Enter a thickness when the in-plane
and out-of-plane thicknesses are identical in both directions.
In-plane:
Enter a thickness used for the calculation of stiffness in the
in-plane direction.
Out-of-Plane:
Enter a thickness used for the calculation of stiffness in the
out-of-plane direction.
Plate
Offset : Offset of a plate section in the element's
local-z direction.
Thickness
Ratio : For a specific location of Offset, enter the distance
as ratio of the offset distance to the plate thickness.
Note
For
example, if the plate thickness is 200mm and thickness ratio is
entered as 0.1, offset distance is 20mm. If In-plane thickness
is different from Out-of-plane thickness, offset distance is determined
based on the In-plane thickness.
Value
: Enter the offset distance directly.
Stiffened
Thickness
ID: Thickness numbers of planar elements
Value:
Select to define sections by directly entering the data for calculating
the stiffness of ribs.
Thickness
for Weight: Equivalent thickness for calculating the weight
Rib
Position: Rib position relative to planar elements
Lower:
Rib placed underside of the planar elements.
Upper:
Rib placed upper side of the planar elements.
yz
section: Stiffness calculation data of rib placed in the
direction of ECS x-axis
xz
section: Stiffness calculation data of rib placed in the
direction of ECS y-axis
Section
Shape List: Select a section shape of the rib.
In-Plane:
Enter a thickness used for the calculation of stiffness in the
in-plane direction.
Out-of-Plane:
Enter a thickness used for the calculation of stiffness in the
out-of-plane direction.
Hu.
Hl: Refer to the guide diagram on the left side of the
dialog box.
User:
User defined rib dimensions
Thickness
for Plate: Thickness data of planar elements
Rib
Position: Rib position relative to planar elements
Lower:
Rib placed underside of the planar elements.
Upper:
Rib placed upper side of the planar elements
yz
section: Stiffness calculation data of rib placed in the
direction of ECS x-axis
xz
section: Stiffness calculation data of rib placed in the
direction of ECS y-axis
Ribs
Exist: Check if ribs exist.
Section
Shape List: Select a section shape of the rib.
Distance
between Ribs: Rib placement spacing
H1,
B1,...: Refer to the guide diagram on the left side of
the dialog box.

Click the button to display the thickness
data table calculated by the input data to calculate the stiffness
of planar elements.
[Details]
DB:
Select the rib section from the standard section DB by countries.
Thickness
of Plate: Thickness data of planar elements
Rib
Position: Rib position relative to planar elements
Lower:
Rib placed underside of the planar elements.
Upper:
Rib placed upper side of the planar elements
yz
section: Stiffness calculation data of rib placed in the
direction of ECS x-axis
xz
section: Stiffness calculation data of rib placed in the
direction of ECS y-axis
Ribs
Exist: Check if ribs exist.
Distance
between Ribs: Rib placement spacing
Sect.
Name: Select the desired DB from the list to the right.

Click the button to display the thickness
data table calculated by the input data to calculate the stiffness
of planar
elements.[Details]
Modification of previously entered
thickness data
Select the thickness to be modified
from the list in the Thickness dialog box and click to modify
the related data.
Removal
of previously entered thickness data
Select the thickness to be deleted
from the list in the Thickness dialog box and click .
To
copy previously entered thickness data
Select the thickness to be copied
from the list in the Thickness dialog box and click .
To
modify thickness data from an existing fn.MGB file
Click and
select the MGB file containing the thickness data or specify a
file name then click .
Thickness
List
Display thickness data contained in the existing fn.MGB file.
Selected
List
Select thickness data to be imported and register them in the Selected
List.
Note
If a fn.MGB is selected, all the thickness data contained in the existing
fn.MGB file are registered in the Selected List.
Numbering
Type
Specify the Import mode for thickness numbers.
Keep
ID
Import the data keeping the same thickness numbers.
New
ID