Fire Proofing

Apply fireproofing thickness information on line member.

 

ΆΖ Call

New

 [Load] Tab > [Gravity] > [Fire Proofing]

 Work Tree [Analysis] Tab > [Fire Proofing] > Right-Click> [Add Fire Proofing]

Modify, Delete

 Work Tree [Analysis] Tab >[Fire Proofing] > Right-Click > [Modify], [Delete]

 

ΆΖ Detail Description

< Fire Proofing Dialog >

 

Property

Add to Self Weight : Consider fire proofing as additional mass and apply in calculation of self weight and mass for seismic load.

Type : Select type of fire proofing

Contour : Shape with defined thickness around the section shape.

Contour (Top Exposed) : Shape of Contour Type with exposed top.

Block : Shape with defined thickness around the Box of section edges.

Block (Top Exposed) : Shape of Block Type which exposed top.

Thickness : Enter the thickness of fire proofing.

Weight Density : Enter the weight density of fire proofing.

Setback

Function to apply Setback on fire proofing at each end of the member.

 