Define the prestress loads to be applied to the selected tendons.
From the Main Menu
select Load > Prestress
Loads > Tendon Prestress Loads
Select Static Loads
> Prestress Loads > Tendon Prestress Loads in the Menu
tab of the Tree
Menu
Load
Case Name
Select a load case. Click
to the right to add new or modify/delete previously defined
Static Load Cases.
Load
Group Name
Assign a load group in
which the tendon prestress load is to be included. Click to the right to add new or modify/delete previously defined
Load Groups.
Select
Tendon for Loading
Select the tendons to
be applied with the prestress load. Multi-select the relevant tendons
from the tendon list with the mouse and click . To delete
the selected tendons click .
Stress
Value
Specify the magnitude
of the tendon prestress.
The prestressing location(s)
may be either or both the beginning or/and end of the tendons.
Stress:
input in stress unit
Force:
input in force unit
1st Jacking
When both ends are stressed, specify which end is stressed first.
Begin:
Jacking Force at the beginning of the tendons
End:
Jacking Force at the end of the tendons
Both:
Jacking Force at both ends of the tendons
Note
In case of Pre-tension load type, the
1st Jacking option of Tendon Prestress Loads will not apply. Therefore,
analysis results will not be affected whichever is selected
Grouting: after n stage
Define the stage at which the tendons are
grouted in the ducts (sheathes). The grouting stage determines the timing
of using the transformed section with the grouted tendons.
Click to include the selected
tendons with prestressing loads in the tendon list. To the
prestressing data, select a tendon, change the data and click Modify.
After selecting unwanted tendons, click to eliminate
the tendons form the list.