Design Code
|
|
|
Enter the design code applicable for strength verification of SRC (Steel-Reinforced Concrete composite) members. |
|
|
|
From the Main Menu select Design > SRC Design Parameter > Design Code.
From the Menu tab of the Tree Menu select Design > SRC Design Parameter > Design Code. |
|
|
The following dialog box is used to enter the data:
SRC Design Code dialog box
Design Code
SRC design code (Default = SSRC79, refer to Note 1)
Apply Special Provisions for Seismic Design
Not available
: Enter the selection and close the dialog box.
: Do not enter the selection and close the dialog box.
Note 1
The available SRC design codes are as follows :
- The allowable stress design of the American SSRC (Structural Stability Research Council) (SSRC79) (available upon request) - Structure Design Code of the Architectural Institutes of Japan(AIJ-SRC01) - Structure Design Code of the Architectural Institutes of Korea (AIK-SRC2K)
Note 2
|
|