Analysis Control - Steady State Analysis  

 

 

<Seepage Steady State Analysis Control>

 

Convergence

Specify the convergence criteria.
 

Maximum Number of Iterations

Enter the maximum number of iterations.
Tolerance

Enter the seepage analysis tolerance. This parameter is the desired difference in the norm of the nodal head vector between two successive iterations (i.e., residual iteration). The iteration process stops if the residual iteration is less than the specified tolerance. If the residual iteration is greater than the specified tolerance, the iteration process continues until it reaches the maximum number of iterations.