Function
Enter the design code applicable for strength verification of SRC (Steel-Reinforced Concrete composite) members.
Call
From the Main Menu select Design > SRC Design Parameter > Design Code.
From the Menu tab of the Tree Menu select Design > SRC Design Parameter > Design Code.
Entry
The following dialog box is used to enter the data:
.jpg)
SRC design code (Default = SSRC79, refer to Note 1)
Not available
: Enter the selection
and close the dialog box.
: Do not enter the selection
and close the dialog box.
Note
1
If the user does not specify the design code, the allowable stress design
(A Specification for the Design of Steel-Concrete Column, 1979) of the
American SSRC (Structural Stability Research Council) will be used.
The available SRC design codes are as follows :
- The allowable stress design of the American SSRC (Structural Stability Research Council) (SSRC79)
(available upon request)
- Structure Design Code of the Architectural Institutes of Japan(AIJ-SRC01)
- Structure Design Code of the Architectural Institutes of Korea (AIK-SRC2K)
Note
2
The allowable stress design of the American SSRC (SSRC79) and the SRC Structure
Design Specifications of the Architectural Institute of Korea (AIK-SRC2K)
can be applied for SRC composite column members.