ERROR [2130]: LIMIT VALUE OF STRESS CONSTRAINT FOR MATERIAL ID=# IS ZERO

 

Cause

 

This error is generated if the material limit stress is "0" when the stress condition is used as the design constraint condition in topology optimization.

 

 

Analysis Type

 

Topology optimization using linear static analysis

 

 

Related Menu

 

Mesh >> Prop./CSys./Func. >> Material...

 

 

Remedy

 

Enter the yield stress of the corresponding material.