WARNING [3503]: FAILED TO WRITE ANALYSIS DATA TO FILE OR READ ANALYSIS DATA FROM FILECauseThis warning may be generated when writing or reading binary files such as temporary files, Restart files and analysis result files used in the analysis. The primary causes for this warning to are as follows:
1. If the disk capacity is insufficient2. If the target work folder is set to Read Only3. If a virus vaccine program prevents creation of any temporary filesAnalysis TypeAll types of analysesRelated MenuTools >> Option >> General >> Application >> Temporary Folder... Remedy1. In case of insufficient disk capacity, secure a sufficient amount of disk capacity or move the model file to a folder with enough disk capacity. 2. If the target work folder is Read Only, change the folder properties. 3. Using the related menu, specify the path of the temporary files to a location with sufficient disk capacity and no Read Only option. 4. Disable the "Live Check" function of the virus vaccine program.
|