WARNING [4009]: NEGATIVE STRENGTH VALUE SPECIFIED # (ID). USING ABSOLUTE VALUECauseThis warning is generated when the tension strength value used to calculate the safety factor has been changed from negative to positive. Analysis TypeAll types of analysesRelated MenuMesh >> Prop./CSys./Func. >> Material...
RemedyEnter a positive tension capacity value for the material of the corresponding ID.
|