WARNING [4049]: MEMBRANE MATERIAL IS RIGID. BENDING & SHEAR MATERIAL WILL BE IGNORED

 

Cause

 

This warning is generated when the membrane material of 2D plate elements has been defined as a rigid material, but the bending or shear material is different from the membrane material.

 

 

Analysis Type

 

All types of analyses

 

 

Related Menu

 

[Not Applicable in FEA NX]

 

Mesh >> Attribute >> Property >> 2D >> Plate...

 

Static/Heat Analysis >> Attribute/CSys/Function >> Property >> 2D >> Plate...

 

Dynamic/Trans.Heat/CFD Analysis >> Attribute/CSys/Function >> Property >> 2D >> Plate...

 

 

Remedy

 

In this case, the bending or shear material is ignored.  Set the bending and shear materials identical to the membrane material to remove the message.