WARNING [4049]: MEMBRANE MATERIAL IS RIGID. BENDING & SHEAR MATERIAL WILL BE IGNOREDCauseThis warning is generated when the membrane material of 2D plate elements has been defined as a rigid material, but the bending or shear material is different from the membrane material. Analysis TypeAll types of analysesRelated Menu[Not Applicable in FEA NX]Mesh >> Attribute >> Property >> 2D >> Plate...
Static/Heat Analysis >> Attribute/CSys/Function >> Property >> 2D >> Plate...
Dynamic/Trans.Heat/CFD Analysis >> Attribute/CSys/Function >> Property >> 2D >> Plate...
RemedyIn this case, the bending or shear material is ignored. Set the bending and shear materials identical to the membrane material to remove the message.
|