WARNING [4020]: IGNORING Y-DIRECTION IN GRAVITY LOAD FOR AXISYMMETRIC PROBLEMCauseThis warning is generated when the gravity is applied in the circumferential direction in axisymmetric problems. Gravity in the circumferential direction is ignored. Analysis TypeAll types of analyses except for explicit dynamic analysisRelated MenuAnalysis >> load >> Self Weight... Remedy
Remove the gravity component in the circumferential direction.
|