Limiting Slenderness Ratio
|
|
|
|
|
|
Use this function to enter the limiting slenderness ratios for members subjected to axial compressive and tensile forces. |
|
|
|
|
|
|
|
From the Main Menu select Design > Common Parameter > Limiting Slenderness Ratio. |
|
|
|
|
|
First, select the members in the model and enter the following:
|
|
: Apply the entered values to the selected members.
: Close the entry Dialog Bar.
Note 1
Apply selectively according to the axial force (tension, compression) acting in the member's local x-direction. When the limiting slenderness ratios are not entered, the following default values are applied :
Compression Member = 200
Tension Member = 300
Note 2
When the values of the limiting slenderness ratios are repeatedly entered for the same member, the values will be updated to the last values entered.
Note 3
The entered values for the limiting slenderness ratios can be reviewed in the data table arranged in the order of element numbers. The user may Modify/Add and Delete items in the data table.
Access the data table following the procedure below.
From the Main Menu select Design > General Design Parameter > General Design Tables > Limiting Slenderness Ratio
From the Tables tab of the Tree Menu select Design Tables > General Design > Limiting Slenderness Ratio.