Check the reinforcing information and design results of SRC members
by numerical components and contours.
From the Main
Menu select Design > SRC Design Result.
Load Cases/Combinations
Select the desired load case, load combination
or envelope.
Click to the right to enter,
add or modify load combinations (refer to Load Cases/Combinations).
Ratio by Components
Select the desired component of the design
results from the following:
Axial:
Axial stress ratio component
Shear-y
: Shear stress ratio component in the direction of the
strong axis
Shear-z
: Shear stress ratio component in the direction of the weak
axis
Bend-y
: Bending stress ratio component due to moment about the
strong axis
Bend-z
: Bending stress ratio component due to moment about the weak axis
Combined
: Maximum combined stress ratio component
Type of Display
Select the types of displays among Contour,
Legend and Values.
Contour
Display the design results by contours.
Ranges:
Assign the contour ranges.
: Assign the coloring ranges
for contour lines. The user may assign specific colors for specific ranges.
Note
Contour Range Max/Min values can be larger than the max/min output values.
If the
Contour Range values exceed the output values, they are entered at Rank
0 and Rank 11.
Number of
Colors : Assign the number of colors for the contour (select among
6, 12, 18 & 24 colors)
Gradient
Fill : Display the color gradient (shading) in the contour.
Draw Contour
Lines : Display the contour lines by colors.
Colors
: Assign or alter the colors of the contour.
Color Tables
: Assign the type of Colors.
: Control the color of each
range in the contour.
Reverse
Contour: Check on to reverse the sequence of color variation in
the
contour.
Contour
Line : Assign the color for contour boundaries.
Element
Edge: Assign the color of element edges to appear in the contour.
Legend
Organize and display various references related
to analysis results either to the right or left of the working window.
Legend Position:
Select the position of the legend in the output window
Rank Value
Type:
Values for Legend (Exponential or fixed values)
Values
Display the selected design result components
by means of numerical values.
The font and color of the numbers can be
controlled in Display
Option.
Note
When
checking the Design Result on the screen, if the design result exceeds
the limit value, the text is marked in red color.
Decimal
Points: Specify decimal points of the displayed numbers
Exp.: Option to express numerical values in exponents
Min &
Max: Display the minimum and maximum values
Abs Max: Display the absolute maximum value
Max: Display only the maximum value
Min: Display only the minimum value
Limit Scale(%):
Set the screen limits for displaying design results relative to the maximum
or minimum value
Note
The default Decimal Points can be controlled in "Preferences".
Reinforcement
Reinforcing results are produced. (Refer
to Note.)
Rebar:
Reinforcing bar diameter and spacing
Area:
Required reinforcing steel area
Type of
Display: Select the type of displays among Contour, Legend and
Values.
Column
Section Size: Display of column section sizes can be scaled.
Value Option:
Specify the number of decimal points for displayed values.
Note.Display of reinforcement
From the V600 of MIDAS/Gen, reinforcing information such as rebar diameter,
rebar spacing and required reinforcing steel area can be checked in 'Concrete
/ SRC Design Result'.
1)
Design results of column
2)
'Rebar' display of column
3)
Reinforcing steel 'Area' display of column
The following outlines the
reinforcing information in Figs. 2) & 3):
a. (Uc): Ratio of axial
stress of the column (N/(fc' X Ag))
b. (As-corner): Number of
corner rebars & rebar area
Ex.) 4-#7 = 4 X 0.6 = 2.4
in2
c & d. (Asy, Asz): Reinforcing
on a single side
e. (Asv): Tie (shear) reinforcing
spacing of column, Sc
Based on the reinforcing
information noted at b, c & d above, the total number of rebars then
becomes,
Check RC member design results by sectional
locations. It can be used only when "Values" of "Type of
Display" is selected.
I, Center,
J: Represent the RC beam member's sectional locations. The user
can not select the locations. It is automatically selected following the
selection of "Max" or "All".
Max:
Maximum values appear at every RC beam member.
All:
Values appear at each location of RC beam members.
: Apply the displayed
rebar information to the selected elements.