Overturning Moment Table

 

 

 

Overturning moments due to static and dynamic loadings are calculated, and the results are tabulated in a spread sheet format.

 

When 'Consider Story Module' under 'Story Shear Force Ratio' is checked in the 'Model/Building/Control Data', accurate shear forces can be obtained for the story overlapping the upper Module and the lower Module.

 

When Modules are defined in Results > Result Tables > Story > Define Module, the Module data is displayed in the first column of the table.

 

"Story Shear Force Ratio" in "Model/Building/Control Data" must be checked for this function, which is checked as the Default.

 

Table Tool in midas Gen offers a variety of powerful built-in functions. Refer to the following items for detail directions:

 

Usage of Table Tool

 

Terminology

 

Familiarize with Usage

 

Basic directions (Cell motion, selection, size control, etc.)

 

Data manipulation (Add, delete, modify data, etc.)

 

Copy/Paste data using clipboard

 

Supplementary Table functions

 

Table Sorting

 

Table format setting

 

Auto-fit column width

 

Graph printing

 

Supplementary functions by Table types

 

Node/Element Table

 

Results Table

 

 

 

From the Main Menu select Results > Result Tables > Story > Overturning Moment Table

 

Select Result Tables > Story > Overturning Moment Table in the Tables tab of the Tree Menu.

 

 

 

 

From Record Activation Dialog, select the load cases/combinations for which Overturning Moment will be calculated.

 

         11-OMT-1.jpg

Record Activation dialog box

 

Refer to Usage of Table Tool and check the following data:

 


    

 0-rectangle.jpg When Modules are not defined

 

 

11-OMT-2.jpg

 

 

Load Case: Load case/Combination

 

Story: Story number

 

Level: Elevation of the Story

 

Story Height: Story (floor to floor) Height

 

Angle: Specify a load direction

 

Note1
For static loads, once the load direction is input as Angle, overturning moment is obtained for the loads applied in the specified direction. For response spectrum loads, a certain overturning moment is generated irrespective of the specified load direction, since in this case the overturning moment is calculated with respect to the direction that is specified when response spectrum loads are entered.

 

1. Reduction Factor(τ)  

 

Reduction Factors for Overturning Moments are applied as follows:

 

(1) 10 stories from the top: 1.0

(2) 20th story from the top and below: 0.8

(3) Between 10th and 20th stories from the top: interpolated between 1.0 and 0.8

 

 

 2. Overturning Moment by Vertical Member Types

 

Value and ratio of the overturning moment in the direction specified by the Angle, which is contributed by the Frame and Wall.

 

 

3. Sum of Story Force * Distance

 

The values from the equation below are multiplied by the 'Scale-up Factor' invoked from 'Set Overturning Moment Parameters'.  The Reduction Factors have not been applied to Overturning Moments here.

 

11-OMT-8.jpg

 

4. Overturning Moment

 

The Reduction Factors have been applied to Overturning Moments here.

 

11-OMT-9.jpg

 

The Reduction Factors for Overturning Moments (τ) are obtained by an approximate method, which are intended to consider the effects of higher modes of a highrise building for the results of static analysis.  IBC2000 states that Define Reduction Factor of Set Overturning Moment Parameters can be set to τ=1.0 for dynamic analysis.

 

 

5. Set Overturning Moment Parameters

 

Right-click on the table and select "Set Overturning Moment Parameters" to enter Scale Factor and Reduction Factor values.

 

Scale Factor

Scale up Factors calculated for dynamic analysis

 

Reduction Factor

Fixed (1.0): Reduction Factor, 1.0, is applied to al the stories.

Auto Calculation: Reduction Factor for each story is automatically calculated as per "1.Reduction Factor".

 

 

 0-rectangle.jpg When Modules are defined

 

The Module colun is generated only when the Modules are defined. Overturning moments are calculated as per the following Note.

 

Note

1. τ : Apply different τ values to upper Modules and apply the greater of those τ values to Base Module.

2. Overturning moment for the top floor of Base Module is not generated.

 

 

11-OMT-3.jpg

 

 

Module: Module name is defined in Define Module

 

Load Case: Load case/Combination

 

Story: Story number

 

Level: Elevation of the Story

 

Story Height: Story (floor to floor) Height

 

Angle: Specify a load direction

 

Note1

For static loads, once the load direction is input as Angle, overturning moment is obtained for the loads applied in the specified direction. For response spectrum loads, a certain overturning moment is generated irrespective of the specified load direction, since in this case the overturning moment is calculated with respect to the direction that is specified when response spectrum loads are entered.

 

1. Reduction Factor(τ)  

 

Reduction Factors for Overturning Moments are applied as follows:

 

(1) 10 stories from the top: 1.0

(2) 20th story from the top and below: 0.8

(3) Between 10th and 20th stories from the top: interpolated between 1.0 and 0.8

 

 

 2. Overturning Moment by Vertical Member Types

 

Value and ratio of the overturning moment in the direction specified by the Angle, which is contributed by the Frame and Wall.

 

 

3. Sum of Story Force * Distance

 

The values from the equation below are multiplied by the 'Scale-up Factor' invoked from 'Set Overturning Moment Parameters'.  The Reduction Factors have not been applied to Overturning Moments here.

 

11-OMT-4.jpg

 

4. Overturning Moment

 

The Reduction Factors have been applied to Overturning Moments here.

 

11-OMT-5.jpg

 

The Reduction Factors for Overturning Moments (τ) are obtained by an approximate method, which are intended to consider the effects of higher modes of a highrise building for the results of static analysis.  IBC2000 states that Define Reduction Factor of Set Overturning Moment Parameters can be set to τ=1.0 for dynamic analysis.

 

 

5. Set Overturning Moment Parameters

 

Right-click on the table and select "Set Overturning Moment Parameters" to enter Scale Factor and Reduction Factor values.

 

Scale Factor

Scale up Factors calculated for dynamic analysis

 

Reduction Factor

Fixed(1.0): Reduction Factor, 1.0, is applied to al the stories.

Auto Calculation: Reduction Factor for each story is automatically calculated as per "1.Reduction Factor".

 

 

    11-OMT-6.jpg

Context Menu (Set Overturning Moment Parameters)

 

       11-OMT-7.jpg

Set Overturning Moment Parameters dialog box