Final Stage
Specify a stage to be considered
as the final construction stage of the heat of hydration analysis.
Last
Stage
Assign the last stage as the true last stage.
Other
Stage
Assign a stage within the overall construction stages as the final
stage. Analysis will be performed only up to the Stage specified
here.
Integration Factor
Enter the Temporal discretization
Factor,
used in heat transfer analysis.
= 0: Forward difference
= 1/2: Crank-Nicolson
method
= 2/3: Galerkin method
= 1: Backward difference
Initial Temperature
Specify the initial temperature used
in the heat transfer analysis.
Element Stress Evaluation
Specify the location in solid elements
for stress output.
Center:
Use the stresses at the centers of the solid elements to represent
the stresses of the individual elements.
Gauss:
Use the stresses at the Gauss points as the nodal stresses.
Nodal
Point: Interpolate the stresses at the Gauss points for
nodal stresses.
Creep & Shrinkage
Account for Creep and Shrinkage in
the analysis.
Type
Select one of the options for inclusion of creep and shrinkage
in the analysis.
Creep
Calculation Method
Select one method for calculating creep between the method using
Code (General) and the method using effective modulus of elasticity
(Effective Modulus).
General
When General is selected, creep and shrinkage are accounted for
according to the Code specified in Time Dependent Material (Creep/Shrinkage).
Convergence
for Creep Iteration
Specify the convergence requirement for ending the repetitive process
in the analysis reflecting creep.
Number
of Iterations: Maximum number of repetitions
Tolerance:
for convergence
Effective Modulus
Effective Modulus of Elasticity is
an approximate calculation method to account for creep.
The reduction factor, phi1, is applied
to Modulus of Elasticity from 0(day) to n1(day). The reduction
factor, phi2, is applied to Modulus of Elasticity after n2 (day).
Between n1 and n2, the reduction factor is interpolated.
Note
If a file of a previous version, which contains creep data defined
by Effective Modulus method, is opened, the related creep data
becomes deleted. The data needs to be redefined.
Use Equivalent Age
by Time & Temperature
Select whether or not to use Equivalent
Age based on Time and Temperature for Heat of Hydration Analysis.
Include Self weight Load
Check this option to include Self
weight. Enter "-1" to consider the Self weight
in the gravity direction.
:
Remove the analysis conditions and do not perform the heat of
hydration analysis.
|